Skip to main content

Table 7 The late occurring complications during intubation procedure

From: Comparison of hypoxemia, intubation procedure, and complications for non-invasive ventilation against high-flow nasal cannula oxygen therapy for patients with acute hypoxemic respiratory failure: a non-randomized retrospective analysis for effectiveness and safety (NIVaHIC-aHRF)

Complications

Cohorts

Comparisons between cohorts

NIV

HCO

Procedure for oxygenation and ventilation

Non-invasive ventilation

High-flow nasal cannula oxygen

Patients included in the analysis

154

161

p-value

Sepsis-related Organ Failure Assessment score at 1

9.89 ± 2.52

10.45 ± 3.52

0.107

Sepsis-related Organ Failure Assessment score at 7

6.12 ± 1.22

6.62 ± 3.15

0.066

Ventilator-associated pneumonia

38 (25)

32 (20)

0.344

Duration of mechanical ventilation (days)

11.12 ± 3.45

11.78 ± 3.11

0.075

Length of stay in the intensive care unit (days)

14.11 ± 3.16

14.22 ± 4.12

0.791

Death within a month

43 (28)

51 (32)

0.538

  1. Constant variables are reported as frequency (percentages) and continuous and ordinal data are demonstrated as mean ± standard deviation (SD)
  2. The Fischer exact test was performed for constant data and the Mann-Whitney U-test was performed for continuous and ordinal data